Pressure Vessels, Filtration Systems and Process Skids

ASME, PED and CRN Flanged Filter Housings

Housing Features:

  • Available in Carbon Steel and Stainless Steel.
  • Stainless Steel construction, High-quality 304 and optional 316L, means no fouling or corrosion and long service life.
  • Plenum chamber design improves drainage from the filter housing when used to coalesce liquids.
  • Vents tapped 1/4" FNPT.
  • Available with F, S and A Series filter elements.
  • EPDM housing seal. Other elastomers available.
Flanged Microfilters 1" - 12"
Model Capacity (scfm) at 100 PSI effective working pressure nominal Connection Flanged Dimensions Number of Filter Elements Maximun
Operating
Pressure
Weight
(lbs)
Flanged Filter Housings
A B
HVM FF-1-XX-# 177 1" 10 16 1 232 24
HVM FF-1.5-XX-# 412 1 1/2" 10 28 1 232 31
HVM FF-2.0-XX-# 853 2" 13 42 1 232 57
HVM FF-2.5-XX-# 1,142 2 1/2" 20 41 1 232 89
HVMFF-3.0-XX-# 1,142 3" 35 52 1 232 352
HVM FF-4.0-XX-# 2,560 4" 39 57 3 232 482
HVM FF-6.0-XX-# 5,120 6" 62 65 3 232 935
HVM FF-8.0-XX-# 8,533 8" 66 70 10 232 1,577
HVM FF-10.0-XX-# 13,653 10" 74 76 16 232 2,037
HVM FF-12.0-XX-# 17,066 12" 74 76 20 232 2,328
*Contact HVM for larger and custom sizes.
Substitute the corresponding material type and element type where appropriate:
XX - CS for Carbon Steel
XX - SS for Stainless Steel
# - F Series Microfilter Element
# - S Series Microfilter Element
# - A Series Activated Carbon

Carbon Steel & Stainless Steel Filter Housings

Housing Features:

  • Victaulic Coupling with double 'O' ring and bayonet for positively locating the element.
  • The 'O' ring eliminates possibility of particle or liquid bypass therefore insuring filtration integrity.
  • Stainless Steel construction, High-quality 304 and optional 316L, means no fouling or corrosion and long service life.
  • Plenum chamber design improves drainage from the filter housing when used to coalesce liquids.
  • Vents tapped 1/4" FNPT.
  • Available with F, S and A Series filter elements.
  • EPDM housing seal. Other elastomers available.
  • Also Available as connection type: BSP, NPT, and Socket Weld.
Threaded Coalescing/Particulate Filters ½" - 3"
Model Capacity (scfm) at 100 PSI G Connection Flanged
Dimensions Maximun Working Pressure (PSIG) Flanged Filter Housings
A B C
HVM-FVT-0.5-XX-# 88 1/2" 11.8 8.3 3.9 232
HVM-FVT-0.75-XX-# 118 3/4" 13.2 10 4.5 232
HVM-FVT-1.0-XX-# 171 1" 15.2 10 4.6 232
HVM-FVT-1.5-XX-# 294 1 1/2" 15.2 10.01 4.6 232
HVM-FVT-2.0-XX-# 459 2 21.7 11.6 5.1 232
HVM-FVT-2.0H-XX-# 677 2 34 13.4 5.1 232
HVM-FVT-2.5-XX-# 853 2 1/2" 34 15.2 5.1 232
HVM-FVT-3.0-XX-# 1,148 3" 45 15.2 5.1 232

Pressure Conversion Factors
Pressure (PSIG) 5 10 14 28 43 57 71 86 100 114 128 148 157 171 186 200 217 232
Correction Factor 0.08 0.18 0.25 0.38 0.50 0.63 0.75 0.88 1 1.13 1.25 1.38 1.5 1.63 1.75 1.88 2 2.13

For maximum flow rate, multiply model flow rate show in the table by correction factor corresponding to the working pressure.

At HVM we are known for customer satisfaction and "Keeping the Pressure On"